Structural strengthening systems
Carbon reinforcement for strengthening existing concrete and masonry structures, supplied as a matched system rather than as separate line items, because consultants and tender documents generally require published compatibility between components.
Specification
| Component | Description |
|---|---|
| Wrap fabric | Unidirectional carbon, specified by areal weight and layer count |
| Primer | Penetrating primer for prepared concrete |
| Saturant resin | Formulated to impregnate fabric on vertical surfaces |
| Levelling putty | For surface defects and pores |
| Plate adhesive | Thixotropic structural paste for bonded plate |
| Plate and rod | Pultruded CFRP plate and near surface mounted rod for flexural work |
A structural paste adhesive is not a saturating resin and the two are not interchangeable. Send us the drawing and the structural calculation and we will confirm which form the job needs.
Where it is used
Column confinement
Fibre wrapped around the section so it resists the concrete spreading sideways under load.
Beam and slab flexural strengthening
Plate or near surface mounted rod bonded to the tension face to add bending capacity.
Shear strengthening
Wrap applied to the web of a member that needs shear capacity it was never designed for.
Seismic retrofit
Confinement applied for ductility, so a column deforms rather than failing suddenly.
Corrosion damage repair
Carbon replacing the effective steel area lost to corrosion, common in coastal structures.
Common questions
Should I use plate, near surface mounted rod or wrap fabric?
It depends on whether you are strengthening in flexure or confining in compression. A beam or slab that needs more bending capacity takes plate or near surface mounted rod on the tension face. A column that needs axial capacity or ductility needs fibre wrapped around the section, which a rigid plate cannot do.
Why is the system supplied as a set rather than as separate items?
Because consultants and tender documents generally require published compatibility between the components. Buying fabric from one source and resin from another is where site problems begin, and a mixed submittal will usually be rejected.
Can I use a plate adhesive to wet out wrap fabric?
No. A structural paste adhesive is not a saturating resin and the two are not interchangeable. The paste is formulated to hold a rigid plate against concrete at a controlled bond line, and it will not impregnate dry fabric properly.
How is wrap fabric specified?
By areal weight in grams per square metre and the number of layers, taken from the structural calculation. Cured thickness is an output of those plus the resin content achieved on site, not something you can order to, so a drawing stating a thickness for a wrap system has usually been copied from a plate specification.
What do you need to quote a strengthening job?
The drawing and the structural calculation. Beyond that: what is being strengthened and in what mode, member dimensions and quantity, fabric areal weight and layer count, fibre orientation, total surface area stated clearly as either net member surface or total fabric to be supplied, and the environmental exposure.
Do I need to allow extra fabric for laps?
Yes. Wrap fabric needs a lap at the closure of each wrap to develop its full capacity, plus further laps where a roll runs out. Calculate the quantity from the wrapped perimeter including laps rather than from the drawn column surface, because a partial second delivery arrives after the crew has demobilised.
Further reading
Areal weight, not thickness
Wrap fabric is specified by grams per square metre and number of layers. Cured thickness is an output of those two things, not something you can order to. If a drawing states a thickness for a wrap system, it has been copied from a plate specification.